Maxi-Signal

Replacement Strobe Lamps

Strobe lamps are high-intensity light sources which use glass and quartz tubing filled with xenon gas to efficiently convert 20 to 50% of the applied electrical energy into optical energy. Similarly, an incandescent light converts only 1 to 3% of the electrical energy into optical energy. An important feature of the xenon strobe lamp is its ability to produce a high peak blue-white light output of short duration. All TOMAR strobe lamps have a trigger coil potted into their assemblies except the low cost model 2001, 5001 and 5002 lamps.

ORDERING INFORMATION

SPECIFICATIONS

Model NumberMinVoltageMaxVoltageAvgWattsBase/ConnectorNote
2001225450103 PIN AMPUSE EXTERNAL TRIGGER
2002225450103 PIN AMP 
300118060020OCTAL 
400122560020OCTAL 
470–RL–CLEAR, RED, BLUE, AMBER200600203 PIN AMP6″ WIRE LEADS
4701 (Note 3)225600203 PIN AMP6″ WIRE LEADS
500122540053 PIN AMPUSE EXTERNAL TRIGGER
500220060013 PIN MOLEXUSE EXTERNAL TRIGGER
600122580040OCTALNON–POLAR
70016002000300OCTAL–LARGEQUARTZ FORCED AIR COOL
9001 (Not Shown)225800203 PIN AMP 
PAR–36–ALL COLORS225600203 PIN AMP 
PAR–36E–RED, BLUE & AMBER225600203 PIN AMP 
PAR–56–ALL COLORS225600403 PIN AMP 
700–R1–ALL COLORS180600203 PIN AMP 

Electrical Notes

  1. All lamps are triggered by discharging a 0.22 MFD capacitor charged to 200 VDC into the trigger connection.
  2. All lamps are polarity sensitive except the 6001.
  3. Rubber friction mount base mounts in 1″ Dia. hole.

WIRING CONNECTORS

Octal (Except 7001)Pin 2 – Anode, Pin 3 – Trigger, Pin6–– Cathode & Trigger Grd.
Octal LargePin 2 – Anode, Pin 3 – Trigger, Pin 5 –
(7001 Only)Trigger Grd, Pin 6 – Cathode
3 Pin AmpPin 1–– Anode, Pin 2 – Cathode,
Mate–N–LokPin 3 – Trigger
5001Pin 1 – Trigger HV, Pin 2 – Cathode, Pin 3 – Anode
2001Pin 1 – Anode, Pin 2 – Trigger, Pin 3 – Cathode