The Super Explosion Proof family of double flash UL listed strobe lights are designed for operation in hazardous areas rated by the NEC as Class I, div 1 & 2 Group C & D and Class II, div. 1 & 2, Group E, F, & G and Class III, div. 1 & 2. They also meet NEMA standards 3, 4, 4X, 7CD and 9EFG, and are marine rated for use in salt water environments. Design features include a housing made of die cast high strength copperfree aluminum alloy with a baked powder epoxy finish, stainless steel hardware, O-ring sealed prestressed glass globe with double pitch acme threads for smooth assembly and ease of maintenance, a flash synchronizing circuit, and an optional guard which need not be removed for relamping. 3/4″ conduit hubs are standard.
SYNCHRONIZING SPECIFICATIONS
SYNCHRONIZING CIRCUIT CONNECTION: This is a low voltage, low power
customer connection which requires one 22 ga twisted pair run between each light. Max length between furthest lights is 3000 feet. Up to 100 lights of different voltages can be synchronized.
SYNCHRONIZING CIRCUIT FEATURES: Each light contains its own flash rate
timing circuit which operates the lamp automatically and a bi-directional synchronizing circuit which overrides the internal timing circuit when connected to another light.
When two or more lamps are synchronized together, failure of any lamp will not prevent other lamps from operating.
Lights may be operated from different power sources, that is a 120 VAC unit may be synchronized with a 12 VDC unit.
SPECIFICATIONS
Lamp Type
6001 Xenon Strobe Lamp
Voltage and Amperage
120 VAC 60 Hz Draws 0.4 A avg. (2.3 A max)
12/24 VDC Draws 4.0/2.0 A avg. (8.0 A max)
Power Supply Output 26 Watts
AC Units DC Units
20 joules 1st flash 20 joules 1st flash
20 joules 2nd flash 20 joules 2nd flash
Flash Rate
40 Flashes per minute
Intensity
Clear 2000 Candela eff.
Amber 1700 Candela eff.
Blue 900 Candela eff.
Red 400 Candela eff.
Green 700 Candela eff.
Size and Weight
14.5″ Tall X 8.75″ Dia. 13 lbs.
(368 mm) (222 mm) (5.9 kg.)
Compliances:
UL 1203 & 1638